Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Dent Mater ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38724334

RESUMO

OBJECTIVES: An increasing number of CAD/CAM (computer-aided design/computer-aided manufacturing) hybrid materials have been introduced to the dental market in recent years. In addition, CAD/CAM hybrid materials for additive manufacturing (AM) are becoming more attractive in digital dentistry. Studies on material microstructures using micro-computed tomography (µ-CT) combined with scanning electron microscopy (SEM) have only been available to a limited extent so far. METHODS: One CAD/CAM three-dimensional- (3D-) printable hybrid material (VarseoSmile Crown plus) and two CAD/CAM millable hybrid materials (Vita Enamic; Voco Grandio), as well as one direct composite material (Ceram.x duo), were included in the present study. Cylindrical samples with a diameter of 2 mm were produced from each material and investigated by means of synchrotron radiation µ-CT at a voxel size of 0.65 µm. Different samples from the same materials, obtained by cutting and polishing, were investigated by SEM. RESULTS: The 3D-printed hybrid material showed some agglomerations and a more irregular distribution of fillers, as well as a visible layered macrostructure and a few spherical pores due to the printing process. The CAD/CAM millable hybrid materials revealed a more homogenous distribution of ceramic particles. The direct composite material showed multiple air bubbles and microstructural irregularities based on manual processing. SIGNIFICANCE: The µ-CT and SEM analysis of the materials revealed different microstructures even though they belong to the same class of materials. It could be shown that µ-CT and SEM imaging are valuable tools to understand microstructure and related mechanical properties of materials.

2.
J Dent ; 144: 104960, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38513937

RESUMO

OBJECTIVES: The present study aims to examine the influence of the build angle on the accuracy (trueness and precision) of 3D printed crowns, table-tops and veneers with a hybrid resin-ceramic material. METHODS: One crown, on table-top and one veneer were printed in five different build angles (0°, 30°, 45°, 60°, 90°) (n = 50) with the digital light processing (DLP) system (Varseo XS, Bego) using hybrid resin (Varseo Smile Crownplus A3, Bego). All printed restorations were scanned using the laboratory scanner (D2000, 3Shape) and matched onto the initial reference design in metrology software (Geomagic Control X, 3D Systems). The root mean square error (RMSE) was calculated between the scanned and reference data. The data was statistically analyzed using the Tukey multiple comparison test and Wilcoxon multiple comparison test. RESULTS: The crown group showed higher trueness at 30° (0.021 ± 0.002) and 45° (0.020 ± 0.002), and table-tops at 0° (0.015 ± 0.001) and 30° (0.014 ± 0.001) (p < 0.0001). Veneers demonstrated higher trueness at 30° (0.016 ± 0.002) (p < 0.0001). All three restoration types demonstrated the lowest trueness at a 90° build angle and portrayed deviations along the z axis. The veneer and table-top groups showed the lowest precision at 90° (veneers: 0.021 ± 0.008; table-tops: 0.013 ± 0.003). The crown group portrayed the lowest precision at 45° (0.017 ± 0.005) (p < 0.0001). CONCLUSION: The build angle of DLP-printed hybrid resin-ceramic restorations influences their accuracy. CLINICAL SIGNIFICANCE: Considering the build angle is important to achieve a better accuracy of 3D-printed resin-ceramic hybrid restorations. This may help predict or avoid the interference points between a restoration and a die and minimize the clinical adjustments.


Assuntos
Cerâmica , Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária , Facetas Dentárias , Impressão Tridimensional , Humanos , Planejamento de Prótese Dentária/métodos , Cerâmica/química , Propriedades de Superfície , Porcelana Dentária/química , Materiais Dentários/química , Processamento de Imagem Assistida por Computador/métodos , Teste de Materiais
3.
Dent J (Basel) ; 12(2)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38392228

RESUMO

Visual color determination is part of the daily routine in dental practice. However, it is not a part of dental education so far. The aim of this study was to evaluate whether visual or digital tooth color determination of 3D-printed teeth is a reliable tool for inexperienced dentistry students. Preclinical dental students evaluated eleven 3D-printed, tooth-shaped samples (VarseoSmile Crown plus, BEGO, Bremen, Germany) of different color shades. Visual shade determination using a reference scale (3D-Master Toothguide (3DM_TG), VITA Zahnfabrik, Bad Säckingen, Germany), followed by a digital color determination using a spectrophotometer (VITA Easyshade V, (ES_V), VITA Zahnfabrik), was performed. Color deviation was calculated in the Lab* color space (ΔE00) and converted into CIELAB 2000. The results were evaluated using the Mann-Whitney U test and the Wilcoxon Rank Sum test (α = 0.05). Significant differences between visual and digital color determination were proven (p < 0.001). Visual color determination (3DM_TG) showed a mean deviation (ΔE00 ± 95%CI) of 6.49 ± 0.47. Digital color determination (ES_V) showed significantly lower mean deviations of ΔE00 of 1.44 ± 0.58. Digital tooth color measurement using a spectrophotometer was a more reliable tool for the color determination of 3D-printed teeth for inexperienced dentistry students.

4.
J Dent ; 142: 104832, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211687

RESUMO

OBJECTIVES: The aim of this study was to evaluate the amount of enamel tooth wear induced by different antagonistic ceramic crown materials in the posterior area within a follow-up period up to 24 months in function. A network meta-analysis was performed to assess the effect of the materials on the mean vertical loss (MVL) of the antagonist enamel tooth surface. DATA: Main search terms used in combination: ceramic, dental materials, metal ceramic, tooth wear and dental enamel. SOURCES: An electronic search was conducted in PubMed/Medline, Embase, and Cochrane CENTRAL plus hand-searching. STUDY SELECTION: Eligibility criteria included clinical studies reporting on MVL on antagonist's tooth up to 24 months following the permanent crown placement. From a total of 5697 articles, 7 studies reporting on 261 crowns for 177 subjects with 3 ceramic materials (Lithium disilicate, metal-ceramic, monolithic zirconia) were included. Among all, metal-ceramic and zirconia caused significantly higher enamel tooth wear on antagonist teeth, representing 82.5 µm [54.4; 110.6]) and 40.1 µm [22.2; 58.0]) more MVL than natural teeth group. In contrast, lithium disilicate showed only 5.0 µm [-48.2; 58.1]) more MVL than occurs on opposing natural teeth. CONCLUSIONS: This systematic review demonstrated that prosthodontic ceramic materials produced significantly more antagonist enamel tooth wear than opposing natural enamel tooth wear, and ceramic material type was correlated to the degree of enamel tooth wear. Additional well-conducted, randomized controlled trials with homogeneous specimens are required due to inadequate sample size and number of the clinical studies included in the analyses. CLINICAL SIGNIFICANCE: The amount of wear caused by different restorative materials has a high influence on the antagonistic natural teeth and should therefore be evaluated intensively by the dentist.


Assuntos
Esmalte Dentário , Desgaste dos Dentes , Humanos , Cerâmica/efeitos adversos , Coroas , Porcelana Dentária/efeitos adversos , Desgaste de Restauração Dentária , Teste de Materiais , Metanálise em Rede , Propriedades de Superfície , Desgaste dos Dentes/etiologia , Zircônio/efeitos adversos , Ensaios Clínicos Controlados como Assunto
5.
J Esthet Restor Dent ; 36(2): 391-401, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37680013

RESUMO

OBJECTIVE: To evaluate the flexural strength and fatigue behavior of a novel 3D-printed composite resin for definitive restorations. MATERIALS AND METHODS: Fifty disc-shaped specimens were manufactured from each of a nanohybrid composite resin (NHC), polymer-infiltrated ceramic network (PICN), and 3D-printed composite resin (3D) with CAD-CAM technology. Biaxial flexural strength (σin ) (n = 30 per group) and biaxial flexural fatigue strength (σff ) (n = 20 per group) were measured using piston-on-three-balls method, employing a staircase approach of 105 cycles. Weibull statistics, relative-strength degradation calculations, and fractography were performed. The results were analyzed with 1-way ANOVA and Games-Howell post hoc test (α = 0.05). RESULTS: Significant differences in σin and σff among the groups (p < 0.001) were detected. The NHC group provided the highest mean ± standard deviation σin and σff (237.3 ± 31.6 MPa and 141.3 ± 3.8 MPa), followed by the PICN (140.3 ± 12.9 MPa and 73.5 ± 9.9 MPa) and the 3D (83.6 ± 18.5 MPa and 37.4 ± 23.8 MPa) groups. The 3D group exhibited significantly lower Weibull modulus (m = 4.7) and up to 15% higher relative strength degradation with areas of nonhomogeneous microstructure as possible fracture origins. CONCLUSIONS: The 3D-printed composite resin exhibited the lowest mechanical properties, where areas of nonhomogeneous microstructure developed during the mixing procedure served as potential fracture origins. CLINICAL SIGNIFICANCE: The clinical indications of the investigated novel 3D-printed composite resin should be limited to long-term provisional restorations. A cautious procedure for mixing the components is crucial before the 3D-printing process, since nonhomogeneous areas developed during the mixing could act as fracture origins.


Assuntos
Cerâmica , Resinas Compostas , Resinas Compostas/química , Teste de Materiais , Cerâmica/química , Resistência à Flexão , Impressão Tridimensional , Desenho Assistido por Computador , Polímeros , Propriedades de Superfície
6.
Dent J (Basel) ; 11(12)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38132413

RESUMO

Visual color determination (VCD) requires color competence and individual training. The aim of this study was to evaluate the deviations in students' VCD with two different reference scales. The research hypothesis was that none of the color references would provide a better result. Participants evaluated nine templates randomly using two reference scales (VITA-classical (VC) and 3D-Master-Toothguide (3DM_TG)). The color distance to the chosen color (ΔEab) was calculated in the CIELAB 2000. The sum's changes in the parameters (LCh°) represented the target variable. Results were evaluated with non-parametric, rank-scaled methods, utilizing the median with a 25%-75% quartile. The significance level (α = 0.05) is determined using the Student's t-test. The mean ± 95%CI (SD) was -1.27 ± -1.09 (3.18); the median ΔE00 was -1.49 (-1.97; 0.96) for dC3DM_TG. The determination with VC showed noticeable differences (dCVC), with a mean ΔE00 of 0.00 ± 0.00 (2.20) and a median ΔE00 of 0.00 (1.17; 1.71). The standard error was 0.19 for the dCVC and 0.27 for the dC3DM_TG. dC3DM_TG vs. dCVC showed significant differences at p < 0.001. The dental student's VCD resulted in color deviations, regardless of the reference template used. The color deviations in hue and chroma were comparable, regardless of the reference scale. VCD's early implementation in dental education is useful to avoid shade misjudgments and potentially expensive remakes of dentures.

7.
Int J Comput Dent ; 0(0): 0, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37823541

RESUMO

AIM: The adjustment and transfer of a stable occlusion can be a major challenge in prosthetic rehabilitations. The aim of this study was to assess a non-invasive treatment option for complex prosthetic rehabilitations and occlusal analyses using 3D-printed restorations clinically. MATERIALS AND METHODS: Eleven patients received a partial or complete rehabilitation with the aid of 3D-printed restorations (n=171). After 12 months of clinical service, all restorations were analyzed using the United States Public Health Service (USPHS) criteria. RESULTS: The 12-month clinical data revealed that 3D-printed restorations showed a survival rate of 84.4%. Complications occurred mostly regarding the anatomical form (7%) or marginal integrity (6AC%) and were consequently rated "Charlie" or "Delta." Color stability and color match of 3D-printed restorations were rated "Alpha" in 83% and 73%, respectively, of all restorations. Marginal inflammation was rated "Alpha" in 89% of all restorations. An excellent surface texture and no secondary caries or postoperative sensitivities (100%) were observed. CONCLUSIONS: 3D-printed restorations might be an alternative treatment option for initiating complex prosthetic rehabilitations. Technical complications rarely occurred. Biological complications did not occur at all. The color stability showed promising results after 12 months of clinical service. However, the results should be interpreted with caution. Long-term results with a high number of restorations should be awaited.

8.
Bioengineering (Basel) ; 10(9)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37760094

RESUMO

To date, no scientific data is available regarding the development and radiographic assessment of approximal caries development after the insertion of 3D-printed, non-invasive veneers of different restoration thicknesses. For the present study, non-invasive veneers were fabricated from two different materials for printing and milling (Vita Enamic and VarseoSmile Crown plus). Three different restoration thicknesses (0.5, 0.7, and 0.9 mm) were selected. After digital design, leaving the approximal space free, and manufacturing of the restorations, adhesive insertion followed. All specimens were placed in a demineralizing solution for 28 days. Subsequently, a radiological and fluorescent examination was performed. The present study showed statistically significant interactions for the day (p < 0.0001) and manufacturing method (p < 0.0001) but not for restoration thickness. Additive manufactured restorations showed less radiological caries progression compared to subtractive manufactured restorations after 21 and 28 days (0.7 and 0.9 mm restoration thickness) (p < 0.0001). DIAGNOdent proved that the restoration thickness affected the caries progression within the subtractive group (p < 0.0001). Radiographic and fluorescence examination showed equivalent results regarding approximal caries assessment. For additive manufacturing, less caries progression was shown without consideration of the restoration thickness.

9.
Int J Comput Dent ; 26(3): 247-255, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36632987

RESUMO

AIM: The aim of the present study was to evaluate the long-term clinical survival and success rate of veneered zirconia crowns with a modified anatomical framework design after 10 years in function. MATERIALS AND METHODS: In total, 36 zirconia crowns were fabricated for 28 patients. An anatomically modified framework design was developed. Crowns were inserted between 2008 and 2009. A follow-up of 19 patients with 28 crowns was conducted in 2020 to document mechanical and biologic parameters. Additionally, a modified version of the pink esthetic score (PES) was documented. Patient satisfaction was assessed using United States Public Health Service (USPHS) criteria. The success and survival rates were calculated using the Kaplan-Meier analysis. RESULTS: After more than 10 years of clinical service, the survival rate of the zirconia crowns was 92.9%. Biologic complications occurred in 12% of the examined crowns, whereas technical complications occurred in 54%. Mostly, chippings (50%) and insufficient marginal gaps (50%) were observed. Most crowns were positively evaluated for more than one technical complication. Periodontal conditions with probing depths of up to 3 mm were comparable with measured values before crown delivery (73% to 75%). Most of the crowns had modified PES values of 10 or higher. Patient satisfaction was high. CONCLUSIONS: The modified framework design led to a high survival rate of the crowns but a relatively low success rate. High patient satisfaction and inconspicuous periodontal conditions were demonstrated. Biologic complications occurred far less frequently than technical complications.


Assuntos
Produtos Biológicos , Doenças Periodontais , Humanos , Cerâmica , Falha de Restauração Dentária , Estética Dentária , Coroas , Zircônio , Porcelana Dentária
10.
Int J Implant Dent ; 7(1): 62, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34282495

RESUMO

PURPOSE: The aim of the present study was to examine the retention force of monolithic zirconia copings cemented with various temporary cements on implant abutments in vitro. METHODS: Sixty exercise implants with pre-screwed implant abutments were embedded in resin. Subsequently, 60 CAD/CAM manufactured zirconia copings were divided into three main groups [Harvard Implant Semi-permanent (HAV), implantlink semi Forte (IMP), Temp Bond NE (TBNE)]. The zirconia copings were cemented on the implant abutments and loaded with 35 N. Specimens were stored in distilled water (37 °C) for 24 h. Half of the test specimens of each group were subjected to a thermocycling (TC) process. Retention force was measured in a universal testing machine. Using magnifying glasses, the fracture mode was determined. Statistical analysis was performed applying the Kruskal-Wallis test, the post hoc test according to Dunn-Bonferroni and a chi-square test of independence. RESULTS: Without TC, IMP showed the highest retention of the three temporary luting agents (100.5 ± 39.14 N). The measured retention forces of IMP were higher than those of HAV (45.78 ± 15.66 N) and TBNE (61.16 ± 20.19 N). After TC, retention was reduced. IMP showed the greatest retentive strength (21.69 ± 13.61 N, three fail outs). HAV and TBNE showed pull-off forces of similar magnitude (17.38 ± 12.77 N and 16.97 ± 12.36 N, two fail outs). The fracture mode analysis showed different results regarding the tested cements before and after TC (facture type before/after TC): IMP (III+II/III), HAV (I/II) and TBNE (III/III). There were clear differences of the fracture modes regarding the examination before and after TC. CONCLUSIONS: Within the limits of this study, IMP showed the highest pull-off forces under the chosen test conditions. All three temporary luting agents showed lower retention forces after TC. Retention values in the individual cement classes were very heterogeneous. Easy cement removal in the crown lumen favours the dominance of adhesive cement fractures on the abutment and adhesive/cohesive cement fractures on the abutment with HAV appears advantageous in case of recementation of the superstructure.


Assuntos
Titânio , Zircônio , Desenho Assistido por Computador , Coroas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA